LEMON Manuals: Even more car manuals for everyone
Home >> Hummer >> 2008 >> H2 4D Utility Wagon >> Repair and Diagnosis >> External Pages >> Different car >> Section 309 (Heating, Ventilation, And Air Conditioning) >> Diagnostic Information and Procedures >> Air Conditioning (A/C) Diagnostics - Pressure Zone C

Air Conditioning (A/C) Diagnostics - Pressure Zone C

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2011 GMC Yukon XL, 2011 GMC Yukon, 2011 Chevrolet Tahoe, 2011 Chevrolet Suburban, and 2011 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
Air Conditioning (A/C) Diagnostics - Pressure Zone C

Step Action Yes No
DEFINITION: The low and the high side pressures are both higher than normal.
  • Restricted Condenser Air Flow
  • Cooling Fan Malfunction
  • Expansion Device Malfunction
1 Were you sent here from the appropriate A/C system performance test? Go to Step 2  Go to Air Conditioning (A/C) System Performance Test (Short Wheel Base) , Air Conditioning (A/C) System Performance Test (Long Wheel Base 1500) , Air Conditioning (A/C) System Performance Test (HP2) , Air Conditioning (A/C) System Performance Test (Long Wheel Base 2500) 
2
  1. With the engine idling, turn ON the A/C.
  2. Inspect for proper cooling fan operation. Refer to Cooling System Description and Operation .
Are the cooling fans ON and operating properly?
Go to Step 3  Go to Step 5 
3 Visually inspect for the following:
  • Restricted air flow.
  • Damaged condenser cooling fins.
  • Inspect for missing or misaligned air baffles.

Do the following conditions exist?
Go to Step 4  Go to Step 6 
4 Repair the air flow restriction.
Is the repair complete?
Go to Step 9  -
5 Repair the cooling fan operation fault. Refer to Symptoms - Engine Cooling .
Is the repair complete?
Go to Step 9  -
6 Feel the liquid line on both sides of the expansion device.Is the temperature the same before and after the expansion device? Go to Step 7  Go to Step 8 
7 Replace the damaged/faulty orifice tube. Refer to Expansion (Orifice) Tube Replacement (W/O C69-HP2) , Expansion (Orifice) Tube Replacement (W/C69-HP2) , Expansion (Orifice) Tube Replacement (W/C69) , Expansion (Orifice) Tube Replacement (W/O C69) .
Is the repair complete?
Go to Step 9  -
8 Air is in the refrigerant system, or the system is overcharged. Refer to the view screen on the J 43600 ACR 2000 Air Conditioning Service Center for foreign gas content in the refrigerant.
Recover and recharge the A/C system. Refer to Refrigerant Recovery and Recharging (Non-HP2) , Refrigerant Recovery and Recharging (HP2) .
Is the repair complete?
Go to Step 9  -
9
  1. Record the low and high side pressures and the I/P outlet air temperature after repairs are performed.
  2. Compare the pressures and outlet temperature to those listed in the A/C Performance Chart. Refer to Air Conditioning (A/C) System Performance Test (Short Wheel Base) , Air Conditioning (A/C) System Performance Test (Long Wheel Base 1500) , Air Conditioning (A/C) System Performance Test (HP2) , Air Conditioning (A/C) System Performance Test (Long Wheel Base 2500) .
Are the readings within the specified ranges?
Go to Step 10  Go to Air Conditioning (A/C) System Performance Test (Short Wheel Base) , Air Conditioning (A/C) System Performance Test (Long Wheel Base 1500) , Air Conditioning (A/C) System Performance Test (HP2) , Air Conditioning (A/C) System Performance Test (Long Wheel Base 2500) 
10 Operate the system in order to verify the repair.
Did you find and correct the condition?
System OK Go to Symptoms - HVAC Systems - Manual
or
Symptoms - HVAC Systems - Automatic