Typical Scan Tool Data
WARNING: This page is about a different car, the 2008 GMC Yukon and 2008 Chevrolet Tahoe. However, it is still accessible from the selected car via links, so may be relevant.
APP Sensor 1 and 2
| Circuit | Normal Range | Short to Ground | Open or High Resistance | Short to Voltage |
|---|---|---|---|---|
| APP Sensor 1 Signal | 0.33-4.75 V | 0 V | 0 V | 5 V |
| APP Sensor 1 5-Volt Reference | 0.33-4.75 V | 0 V | 0 V | 5 V |
| APP Sensor 1 Low Reference | 0.33-4.75 V | - | 4.96 V | - |
| APP Sensor 2 Signal | 0.33-2.50 V | 0 V | 0 V | 5 V |
| APP Sensor 2 5-Volt Reference | 0.33-2.50 V | 0 V | 0 V | 5 V |
| APP Sensor 2 low Reference | 0.33-2.50 V | - | 4.92 V | - |