Starter Solenoid Does Not Click
WARNING: This page is about a different car, the 2007 Hummer H2. However, it is still accessible from the selected car via links, so may be relevant.
Starter Solenoid Does Not Click
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: Starting and Charging Schematics | |||
| 1 | Did you preform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle |
| 2 | Turn the ignition switch to the START position. Does the engine crank? |
Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
| 3 | Turn the ignition switch to the START position. Does the starter motor relay click? |
Go to Step 11 | Go to Step 4 |
| 4 |
|
Go to Step 7 | Go to Step 5 |
| 5 | Inspect for poor connections at the PCM connector, underhood fuse block, or ignition switch harness connector. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 29 | Go to Step 6 |
| 6 | Test the supply voltage circuit of the crank voltage circuit and crank fuse for an open or high resistance. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 29 | Go to Step 27 |
| 7 |
|
Go to Step 19 | Go to Step 8 |
| 8 |
|
Go to Step 9 | Go to Step 10 |
| 9 |
|
Go to Step 17 | Go to Step 14 |
| 10 |
|
Go to Step 18 | Go to Step 15 |
| 11 |
|
Go to Step 12 | Go to Step 23 |
| 12 | Connect a 30-amp fused jumper between the battery positive voltage circuit of the starter motor relay switch circuit and the supply voltage circuit of the starter solenoid. Does the engine crank? |
Go to Step 17 | Go to Step 13 |
| 13 | Does the fuse in the jumper open? | Go to Step 24 | Go to Step 16 |
| 14 | Test the control circuit of the starter motor relay for an open or high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
Go to Step 29 | Go to Step 25 |
| 15 | Test the supply voltage circuit of the starter motor relay coil circuit for an open or high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
Go to Step 29 | Go to Step 21 |
| 16 | Test the supply voltage circuit of the starter solenoid for an open or high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
Go to Step 29 | Go to Step 22 |
| 17 | Inspect for poor connections at the starter motor relay. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 29 | Go to Step 25 |
| 18 | If equipped with an automatic transmission, inspect for a poor connection at the PNP switch harness connector. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. If OK, perform the Park/Neutral Position Switch Adjustment
for the 4L60-E/4L65-E transmission. Did you find and correct the condition? |
Go to Step 29 | Go to Step 26 |
| 19 | Inspect for poor connections at the harness connector of the PCM. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 29 | Go to Step 20 |
| 20 | Replace the PCM. Refer to Control Module References
for replacement, setup, and programming. Did you complete the replacement? |
Go to Step 29 | - |
| 21 | Inspect for poor connections at the ignition switch harness connector. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 29 | Go to Step 27 |
| 22 | Inspect for poor connections at the starter solenoid. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 29 | Go to Step 28 |
| 23 | Repair the open or high resistance in the battery positive voltage circuit of the starter motor relay switch circuit. Refer to Wiring Repairs
. Did you complete the repair? |
Go to Step 29 | - |
| 24 | Repair the short to ground in the supply voltage circuit of the starter solenoid. Refer to Wiring Repairs
. Did you complete the repair? |
Go to Step 29 | - |
| 25 | Replace the starter relay. Refer to Relay Replacement (Attached to Wire Harness)
or Relay Replacement (Within an Electrical Center)
. Did you complete the replacement? |
Go to Step 29 | - |
| 26 | Replace the PNP switch. Refer to Park/Neutral Position Switch Replacement
. Did you complete the replacement? |
Go to Step 29 | - |
| 27 | Replace the ignition switch. Refer to Ignition and Start Switch Replacement
. Did you complete the replacement? |
Go to Step 29 | - |
| 28 | Replace the starter. Refer to Starter Motor Replacement . Did you complete the replacement? |
Go to Step 29 | - |
| 29 | Operate the system for which the symptom occurred. Did you correct the condition? |
System OK | Go to Step 2 |