Remote Start Activation
The following describes the HVAC control head functionality upon receiving the remote start active serial data message and a power mode status is set to off/awake. The outside air temperature (OAT) sensor on automatic systems, is utilized to determine the moding of the following features: Blower Mode, Bi-level, Floor, Defrost, Recirc and Rear Defrost. These features are determined by the IAT during activation sequence and are maintained for the duration of engine run time. Calibratable temperatures are utilized to provide low, mid and high temperature ranges for the selectable feature. Blower and mode have the range to select any valid feature positions. When the remote start active serial data is received, ignition-OFF loop HVAC algorithms will act the same as if a run power mode was received, i.e. re-calibration, afterblow, ignition-OFF motor positioning etc. The OFF timer and the ignition ON timer have the functionality as in the Run mode.
The remote start system operates in one of three zones of operation:
- Cold ambient temperature that is below 10°C (50°F)
- Hot ambient temperature that is above 30°C (86°F)
- Mid ambient temperature that is anything between the cold and hot values
- In cold ambient, the system uses 74°F setpoint, auto blower, defrost mode, rear defrost and/or heated mirrors on, heated seats on, rear in mimic.
- In mid ambient, the system uses 74°F setpoint, auto blower, auto mode, rear in mimic.
- In hot ambient, the system uses 74°F setpoint (60°F setpoint in 2008), auto blower, auto mode, rear in mimic.