- Inspect the CMP O-ring seal for cuts or damage. If the seal is not cut or damaged, it may be used again.
- Lubricate the O-ring seal with clean engine oil.
- Install the O-ring seal (704) onto the sensor.
- Instal the CMP sensor (703) to the front cover.
- Install the CMP sensor wire harness (737).
- Connect the CMP sensor wire harness electrical connectors to the CMP sensor and the CMP actuator magnet.
- Install the 2 CMP sensor wire harness bolts (738).
Tighten: Tighten the bolts to 12 N.m (106 lb in).
- Finger tighten the top CMP sensor wire harness bolt. Using a box wrench through an opening in the harmonic balancer, tighten the bolt an additional 1/4 turn (90 degrees).
- Connect the engine wiring harness electrical connector (1) to the CMP sensor wire harness.
- Lower the vehicle.
NOTE:
Refer to Fastener Notice
.