Circuit/System Description

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2008 GMC Yukon XL, 2008 GMC Yukon, 2008 Chevrolet Tahoe, 2008 Chevrolet Suburban, and 2008 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.

The hybrid engine cooling fan system consists of two electrical cooling fans, two resistors, three engine control module (ECM) fan output control drivers, and five fan relays. The relays are arranged in a series/parallel configuration that allows the ECM to operate the fans at low, medium, or high speed depending on engine cooling requirements. The ECM controls the five relays by grounding the relay control circuits.

During low speed operation, the ECM supplies the ground path for the FAN LO relay control circuit. This energizes the FAN LO relay coil, closes the relay contacts, and supplies battery positive voltage from the low fan fuse through the cooling fan motor supply voltage circuit to the left cooling fan. The ground path for the left cooling fan is through the de-energized FAN CNTRL relay, through the right cooling fan in-line resistor, and through the right cooling fan. The result is a series circuit with both fans running at low speed.

During medium speed operation the ECM grounds one control circuit that energizes a bank of three relays consisting of the FAN Mid 1 relay, the FAN CNTRL relay, and the FAN Mid 2 relay. When these three relays are energized the Mid 1 relay supplies battery voltage to the left cooling fan through the left cooling fan resistor. A ground path is provided for the left fan through the energized FAN CNTRL relay. At the same time the Mid 2 relay is energized which applies battery voltage to the right cooling fan through the right cooling fan resistor. The result is a parallel circuit where each fan has voltage applied through a resistor which causes each fan to operate at reduced speed.

During high speed operation the ECM grounds all three relay control circuits which activates all five relays. This allows full battery voltage to be applied to the right cooling fan from the FAN HI relay, and full battery voltage to be applied to the left fan from the FAN LO relay. The left fan is grounded through the FAN CNTRL relay. In this arrangement each fan has full battery voltage applied and each fan has its own ground path. The result is a parallel circuit with both fans running at high speed.

Refer to Engine Cooling Schematics .