Circuit/System Description
Air Temperature Sensor
The air temperature sensors are a 2-wire negative temperature co-efficient thermistor.
A signal and low reference circuit enables the sensor to operate. As the air temperature surrounding the sensor increases, the sensor resistance decreases. The sensor signal voltage decreases as the resistance decreases. The sensor operates within a temperature range between -40 to +101°C (-40 to +215°F). The sensor signal varies between 0-5 volts. The input of the duct air temperature sensors are different from the ambient and inside air temperature sensors. The HVAC control module converts the signal to a range between 0-255 counts. As the air temperature increases the count value will decrease. If the HVAC control module or auxiliary HVAC control module detects a malfunctioning sensor, then the control module software will use a defaulted air temperature value. The default value for the ambient air temperature sensor will be displayed on the scan tool.