LEMON Manuals: Even more car manuals for everyone
Home >> Hummer >> 2008 >> H2 4D Utility Wagon >> Repair and Diagnosis >> External Pages >> Different car >> Section 188 (HVAC System - Manual) >> Description and Operation >> Air Delivery Description and Operation >> Air Speed >> Auxiliary Blower Motor Control Processor

Auxiliary Blower Motor Control Processor

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2008 GMC Yukon XL, 2008 GMC Yukon, 2008 Chevrolet Tahoe, 2008 Chevrolet Suburban, and 2008 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.

The auxiliary blower motor control processor is an interface between the auxiliary HVAC control module and the rear blower motor. The auxiliary blower motor control processor monitors supply voltage and ground circuits to the rear blower motor. The auxiliary HVAC control module provides a pulse width modulation (PWM) signal to the control processor in order to command the blower motor speed. The auxiliary blower motor control processor uses the blower motor ground as a low side control to adjust the blower motor speed.

The blower motor forces air to circulate within the vehicles interior. The vehicle operator determines the blower motors speed by placing the blower motor switch in a desired speed position or by selecting automatic operation. In manual operation, once a blower speed is selected, the blower speed remains constant, until a new speed is selected. In automatic operation, the HVAC control module will determine what blower speed is necessary in order to achieve or maintain a desired temperature.

As the requested blower speed increases, the following conditions occur:

As the requested blower speed decreases, the following conditions occur: