Circuit/System Description
The drive motor generator battery control module is also referred to as the battery energy control module (BECM). The BECM will diagnose its own systems and determine when a fault condition is present. Diagnostics and system status is communicated from the BECM to the hybrid powertrain control module (HPCM) through the Hybrid LAN communication circuit. The HPCM is the host controller for diagnostic trouble code (DTC) information.
The drive motor generator battery has four hybrid battery temperature sensors. The hybrid battery temperature sensors are located on the top of the hybrid batteries. The temperature sensor is a variable resistor that measures the temperature of the hybrid batteries. The control module supplies 5 volts to the signal circuit and a ground for the low reference circuit. The hybrid battery temperature sensor resistance changes with battery temperature. The lower the temperature, the higher the resistance of the sensor. The higher the temperature, the lower the resistance of the sensor. The BECM uses the battery temperature sensors to determine the hybrid battery temperature to control the battery cooling fan operation.