Test Description
WARNING: This page is about a different car, the 2007 Hummer H2. However, it is still accessible from the selected car via links, so may be relevant.
The numbers below refer to the step numbers in the diagnostic table.
- 8: This step ensures that the lower air temperature sensors operate properly. The LH and RH Heater Duct Actual parameter count values should lower as the air temperature of the ducts get warmer. If there is a high resistance in either of the air temperature sensors circuits or the sensor itself, then the count value of the affected sensor would remain high.
- 9: This step ensures that the upper air temperature sensors operate properly. The LH and RH AC Duct Actual parameter count values should lower as the air temperature of the ducts get warmer. If there is a high resistance in either of the air temperature sensors circuits or the sensor itself, then the count value of the affected sensor would remain high.
- 15: Use the following table to determine that the recorded scan tool values are within range for the recorded probe temperatures.
Too Cold in Vehicle
| Temperature °C | Temperature °F | Scan Tool Display |
|---|---|---|
| 0-4 | 32-40 | 206-175 counts |
| 5-9 | 41-49 | 194-161 counts |
| 10-14 | 50-58 | 180-145 counts |
| 15-19 | 59-67 | 166-133 counts |
| 20-24 | 68-76 | 150-119 counts |
| 25-29 | 77-85 | 136-106 counts |
| 30-34 | 86-94 | 121-93 counts |
| 35-39 | 95-103 | 107-81 counts |
| 40-44 | 104-112 | 94-69 counts |
| 45-49 | 113-121 | 83-59 counts |
| 50-54 | 122-130 | 72-51 counts |
| 55-59 | 131-139 | 63-44 counts |
| 60-64 | 140-148 | 55-37 counts |
Too Cold in Vehicle
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature can not be adjusted, or heating is insufficient. |
||||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | - | Go to Step 2 | Go to Diagnostic System Check - Vehicle |
| 2 |
IMPORTANT:
If during this diagnostic procedure the HVAC control module is disconnected a recalibration of actuators must be performed to avoid misdiagnosis.
|
- | Go to Diagnostic Trouble Code (DTC) List - Vehicle | Go to Step 3 |
| 3 |
|
- | Go to Step 4 | Go to Blower Motor Inoperative |
| 4 | Does the blower motor operate in all desired speed positions? | - | Go to Step 5 | Go to Blower Motor Malfunction |
| 5 |
|
- | Go to Step 6 | Go to Air Recirculation Malfunction |
| 6 |
|
- | Go to Step 7 | Go to HVAC Compressor Clutch Does Not Disengage |
| 7 | Perform the Heating Performance Diagnostic. Refer to Heating Performance Diagnostic
. Did you find and correct the condition? |
- | Go to Step 29 | Go to Step 08 |
| 8 |
|
- | Go to Step 9 | Go to Step 21 |
| 9 |
|
- | Go to Step 10 | Go to Step 21 |
| 10 | Check the air temperature sensors for proper installation. Refer to the following procedures:
Did you find and correct the condition? |
- | Go to Step 29 | Go to Step 11 |
| 11 |
|
- | Go to Step 13 | Go to Step 12 |
| 12 |
|
- | Go to Step 18 | Go to Step 17 |
| 13 |
|
220 Counts | Go to Step 14 | Go to Step 23 |
| 14 |
|
- | Go to Step 15 | Go to Step 19 |
| 15 |
|
- | Go to Diagnostic Aids | Go to Step 16 |
| 16 |
|
- | Go to Step 24 | Go to Step 22 |
| 17 | Test the fan motor supply voltage circuit of the inside air temperature sensor assembly for an open, a high resistance, or a short to ground. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
- | Go to Step 29 | Go to Step 24 |
| 18 | Test the ground circuit of the inside air temperature sensor assembly for an open or high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition |
- | Go to Step 29 | Go to Step 20 |
| 19 |
|
- | Go to Step 24 | Go to Step 20 |
| 20 | Inspect for poor connections at the harness connector of the inside air temperature sensor assembly. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
- | Go to Step 29 | Go to Step 27 |
| 21 | Test the signal circuit and the low reference circuit of the appropriate air temperature sensor for a high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
- | Go to Step 29 | Go to Step 22 |
| 22 | Inspect for poor connections at the harness connector of the suspect air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
- | Go to Step 29 | Go to Step 25 |
| 23 | Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
- | Go to Step 29 | Go to Step 26 |
| 24 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
- | Go to Step 29 | Go to Step 28 |
| 25 | Replace the suspect air temperature sensor. Refer to one of the following procedures:
Did you complete the replacement? |
- | Go to Step 29 | - |
| 26 | Replace the sunload sensor. Refer to Sun Load Sensor Replacement . Did you complete the replacement? |
- | Go to Step 29 | - |
| 27 | Replace the inside air temperature sensor assembly. Refer to Inside Air Temperature Sensor Assembly Replacement . Did you complete the replacement? |
- | Go to Step 29 | - |
| 28 | Replace the HVAC control module. Refer to Control Module References
for replacement, setup, and programming. Did you complete the replacement? |
- | Go to Step 29 | - |
| 29 | Operate the system in order to verify the repair. Did you correct the condition? |
- | System OK | Go to Step 3 |