Test Description
WARNING: This page is about a different car, the 2007 Hummer H2. However, it is still accessible from the selected car via links, so may be relevant.
- 2: This step verifies that the HVAC control module Fan Up Switch parameter matches the requested state of the blower motor switch.
- 3: This step verifies that the HVAC control module Fan Down Switch parameter matches the requested state of the blower motor switch.
Blower Motor Malfunction
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor operates in at least one speed position. |
||||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | - | Go to Step 2 | Go to Diagnostic System Check - Vehicle |
| 2 |
|
- | Go to Step 3 | Go to Step 10 |
| 3 |
|
- | Go to Step 4 | Go to Step 10 |
| 4 | Place the blower motor switch in each speed position. Does the blower motor operate at the desired speeds? |
- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 5 |
| 5 |
|
10-14 V | Go to Step 6 | Go to Step 8 |
| 6 |
|
4.5-5.5 V | Go to Step 9 | Go to Step 7 |
| 7 | Test the control circuit of the blower motor control processor for a high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 9 |
| 8 | Test the battery positive voltage circuit of the blower motor control processor for a high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 11 |
| 9 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 12 |
| 10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 13 |
| 11 | Repair a high resistance in the ground circuit of the blower motor control processor. Refer to Circuit Testing
. Did you complete the repair? |
- | Go to Step 14 | - |
| 12 | Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement . Did you complete the replacement? |
- | Go to Step 14 | - |
| 13 | Replace the HVAC control module. Refer to Control Module References
for replacement, setup, and programming. Did you complete the replacement? |
- | Go to Step 14 | - |
| 14 | Operate the system in order to verify the repair. Did you correct the condition? |
- | System OK | Go to Step 2 |