Test Description
WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2007 GMC Yukon XL, 2007 GMC Yukon, 2007 Chevrolet Tahoe, 2007 Chevrolet Suburban, and 2007 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
The numbers below refer to the step numbers on the diagnostic table.
- 2: This step verifies that the HVAC control module Fan Up Switch parameter matches the requested state of the blower motor switch.
- 3: This step verifies that the HVAC control module Fan Down Switch parameter matches the requested state of the blower motor switch.
Blower Motor Malfunction
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor operates in at least one speed position. |
||||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | - | Go to Step 2 | Go to Diagnostic System Check - Vehicle |
| 2 |
|
- | Go to Step 3 | Go to Step 10 |
| 3 |
|
- | Go to Step 4 | Go to Step 10 |
| 4 | Place the blower motor switch in each speed position. Does the blower motor operate at the desired speeds? |
- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 5 |
| 5 |
|
10-14 V | Go to Step 6 | Go to Step 8 |
| 6 |
|
4.5-5.5 V | Go to Step 9 | Go to Step 7 |
| 7 | Test the control circuit of the blower motor control processor for a high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 9 |
| 8 | Test the battery positive voltage circuit of the blower motor control processor for a high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 11 |
| 9 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 12 |
| 10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 13 |
| 11 | Repair a high resistance in the ground circuit of the blower motor control processor. Refer to Circuit Testing
. Did you complete the repair? |
- | Go to Step 14 | - |
| 12 | Replace the blower motor control processor. Refer to Blower Motor Control Module Replacement
. Did you complete the replacement? |
- | Go to Step 14 | - |
| 13 | Replace the HVAC control module. Refer to Control Module References
for replacement, setup, and programming. Did you complete the replacement? |
- | Go to Step 14 | - |
| 14 | Operate the system in order to verify the repair. Did you correct the condition? |
- | System OK | Go to Step 2 |