Removal Procedure
WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2007 GMC Yukon XL, 2007 GMC Yukon, 2007 Chevrolet Tahoe, 2007 Chevrolet Suburban, and 2007 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
IMPORTANT:
An 8-digit identification number is located on the fuel rail. Refer to this identification number when servicing or when part replacement is required.
- Remove the air cleaner outlet duct. Refer to Air Cleaner Resonator Outlet Duct Replacement .
- Relieve the fuel system pressure. Refer to Fuel Pressure Relief .
- Remove the engine wiring harness bracket nut (1).
- Disconnect the engine wiring harness electrical connector (2) from the evaporative emission (EVAP) purge solenoid.
- Disconnect the engine wiring harness electrical connector (3) from the generator.
- Disconnect the engine wiring harness electrical connector (4) from the manifold absolute pressure (MAP) sensor.
- Remove the connector position assurance (CPA) retainer (2).
- Disconnect the engine wiring harness electrical connector (1) from the ignition coil main electrical connector.
- Disconnect the engine wiring harness electrical connectors (3) from the fuel injectors, perform the following:
- Mark the connectors to their corresponding injectors to ensure correct reassembly.
- Pull the CPA retainer on the connector up 1 click.
- Push the tab on the connector in.
- Disconnect the fuel injector electrical connector.
- Remove the CPA retainer (2).
- Disconnect the engine wiring harness electrical connector (1) from the ignition coil main electrical connector.
- Disconnect the engine wiring harness electrical connector (3) from the electronic throttle control.
- Disconnect the engine wiring harness electrical connectors (7) from the fuel injectors, perform the following:
- Mark the connectors to their corresponding injectors to ensure correct reassembly.
- Pull the CPA retainer on the connector up 1 click.
- Push the tab on the connector in.
- Disconnect the fuel injector electrical connector.
- Remove the engine wiring harness clip (4) from the generator battery jumper cable.
- Remove the engine wiring harness clip (6) from the ignition coil bracket stud.
- Remove the negative battery cable stud (1) from the right cylinder head.
- Remove the negative battery cable terminal (2) and engine wiring harness ground terminal (3) from the cylinder head.
- Remove the engine wiring harness clip bolt (3) from the generator bracket.
- Gather the branches of the engine wiring harness and reposition the aside.
- Remove the fuel rail crossover pipe retainer screws (2).
- Remove the fuel rail crossover pipe retainers (3).
- Remove the fuel rail crossover pipe (1) from the fuel rails.
- Remove and discard the fuel rail crossover pipe O-ring seals (4).