Installation Procedure
WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2007 GMC Yukon XL, 2007 GMC Yukon, 2007 Chevrolet Tahoe, 2007 Chevrolet Suburban, and 2007 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
- Inspect the CMP O-ring seal for cuts or damage. If the seal is not cut or damaged, it may be used again.
- Lubricate the O-ring seal with clean engine oil.
- Install the O-ring seal (704) onto the sensor.
- Instal the CMP sensor (703) to the front cover.
- Install the CMP sensor wire harness (737).
- Connect the CMP sensor wire harness electrical connectors to the CMP sensor and the CMP actuator magnet.
- Install the 3 CMP sensor wire harness bolts (738).
Tighten: Tighten the bolts to 12 N.m (106 lb in).
- Connect the engine wiring harness electrical connector (1) to the CMP sensor wire harness.
- Lower the vehicle.
NOTE:
Refer to Fastener Notice
.