Diagnostic Aids
- The EVAP system can be filled with smoke more quickly and completely by opening the system opposite the end where the smoke is injected. When injecting smoke at the service port remove the fuel fill cap, or temporarily leave the vent open, until smoke is observed then close the system and continue testing. If using a fuel cap adapter at the filler neck, use the J 41413-VLV at the service port to allow the system to fill faster. See Special Tools .
- To help locate intermittent leaks using the J 41413-200 , move all EVAP components while observing smoke with the J 41413-SPT . See Special Tools .
- Individual components can be isolated and tested using adapters in the J 41413-300 .
- A condition may exist where a leak in the EVAP system only exists under a vacuum condition. This type of leak may be detected by using the scan tool Purge/Seal function to create a vacuum in the EVAP system and then observe the FTP parameter for vacuum decay.