Vac-N-Fill Procedure
IMPORTANT:
To prevent boiling of the coolant/water mixture in the vehicles cooling system, do not apply vacuum to a cooling system above 49°C (120°F). The tool will not operate properly when the coolant is boiling.
- Install the J 42401 . See Special Tools .
- Attach the Van-N-Fill cap to the vehicles coolant fill port.
- Attach the vacuum gage assembly to the Vac-N-Fill cap.
- Attach the fill hose to the barb fitting on the vacuum gage assembly.
Ensure that the valve is closed.
- Pour the coolant mixture into the graduated reservoir.
- Place the fill hose in the graduated reservoir.
- Install the vacuum tank on the graduated reservoir with the fill hose routed through the cut-out area in the vacuum tank.
- Attach the venture assembly to the vacuum tank.
- Attach a shop air hose to the venture assembly.
Ensure the valve on the venture assembly is closed.
- Attach the vacuum hose to the vacuum gage assembly and the vacuum tank.
- Clamp off the overflow hose.
- Open the valve on the venture assembly. The vacuum gage will begin to rise and a hissing noise will be present.
- Continue to draw vacuum until the needle stops rising. This should be 610-660 mm Hg (24-26 in Hg).
Cooling hoses may start to collapse. This is normal due to vacuum draw.
- To aid in the fill process, position the graduated reservoir above the coolant fill port.
- Slowly open the valve on the vacuum gage assembly. When the coolant reaches the top of the fill hose, close the valve. This will eliminate air from the fill hose.
- Close the valve on the venture assembly.
- If there is a suspected leak in the cooling system, allow the system to stabilize under vacuum and monitor for vacuum loss.
If vacuum loss is observed, refer to Loss of Coolant .
- Open the valve on the vacuum gage assembly. The vacuum gage will drop as coolant is drawn into the system.
- Once the vacuum gage reaches zero, close the valve on the vacuum gage assembly and repeat steps 11-17.
- Remove the J 42401 . See Special Tools .
- Detach the Vac-N-Fill cap from the vehicles coolant fill port.
- Add coolant to the system as necessary.
- Inspect the concentration of the coolant mixture using J 26568 . See Special Tools .
- Detach the vacuum hose form the vacuum gage assembly.
- Attach the extraction hose to the vacuum hose.
- Open the valve on the venture assembly to start a vacuum draw.
- Use the extraction hose to draw out coolant to the proper level.
- The vacuum tank has a drain valve on the bottom of the tank. Open the valve to drain coolant from the vacuum tank into a suitable container for disposal.
IMPORTANT:
Use a 50/50 mixture of DEX-COOL antifreeze and clean, drinkable water. Always use more coolant than necessary. This will eliminate air from being drawn into the cooling system.
IMPORTANT:
Prior to installing the vacuum tank onto the graduated reservoir, ensure that the drain valve located on the bottom of the tank is closed.
IMPORTANT:
After filling the cooling system, the extraction hose can be used to remove excess coolant to achieve the proper coolant level.