Circuit/System Testing
- Ignition OFF, disconnect the harness connector X5 at the BCM.
- Test for greater than 70 ohms between the RAP/ACCY relay coil control circuit terminal 11 and ground.
- If less than the specified range, test the control circuit for a short to ground. If the circuit tests normal, replace the underhood fuse block.
- If all circuits test normal, replace the underhood fuse block.