Circuit/System Testing
- Disconnect the seat adjuster or power lumbar switch connector.
- Verify that a test lamp illuminates when connected from battery voltage to the ground circuit terminal.
- If the test lamp does not illuminate, repair the ground circuit for an open/high resistance.
- Verify that a test lamp illuminates when connected from the battery supply circuit terminal to ground.
- If the test lamp does not illuminate, repair the battery supply circuit for an open/high resistance or short to ground.
- Connect the seat adjuster or power lumbar switch connector and disconnect the inoperative motor assembly connector.
- Connect a test lamp across the inoperative motor control circuit terminals.
- Verify that the test lamp illuminates when the appropriate switch is pressed.
- If the test lamp does not illuminate, repair the motor circuits for an open/high resistance or short to ground. If the circuits test normal replace the seat adjuster or power lumbar switch.
- If the circuits test normal, replace the inoperative motor assembly.