Circuit/System Testing
- Ignition OFF, disconnect the underhood fuse block.
- Connect a 60A fused jumper from the battery supply terminal in connector X6 to connector X5 terminal F2.
- Connect a test lamp from the relay control circuit in connector X5 terminal K3 to ground.
- Command the Wiper Relay ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the body control module.
- If the test lamp is always OFF, test for a short to ground or an open/high resistance on the control circuit. If the circuit tests normal, replace the body control module.
- If all circuits test normal, replace the underhood fuse block.
IMPORTANT:
The underhood fuse block bottom view illustration is an inverted view of the connectors in the bracket assembly.