Circuit/System Testing
- Ignition OFF, disconnect the harness connector at an affected vanity mirror lamp.
- Verify that a test lamp illuminates between the ground circuit terminal B and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, verify that a test lamp illuminates between the inadvertent power supply circuit terminal A and ground.
- If the test lamp does not illuminate, test the inadvertent power supply circuit for a short to ground or an open/high resistance. If the circuit tests normal replace the BCM.
- Connect the harness connector at the vanity mirror lamp, and remove the vanity lamp bulb.
- Connect a test lamp across the bulb terminals
- Ignition ON, operate the vanity mirror lamp on and off. The test lamp should turn on and off when changing between the commanded states.
- If the test lamp is always on, replace the affected vanity mirror lamp.
- If the test lamp is always off, replace the affected vanity mirror lamp.
- If all circuits test normal, test or replace the affected vanity lamp bulb.