Circuit/System Testing
- Ignition OFF, disconnect the X1 harness connector at the turn signal/multifunction switch.
- Verify that a test lamp iluminates between the ground circuit terminal C and ground.
- If the test lamp does not illuminate, test the ground circuit for an open/high resistance.
- Ignition ON, verify the scan tool hazard lamp switch parameter is Inactive.
- If not the specified value, test the signal circuit terminal G for a short to ground. If the circuit tests normal, replace the BCM.
- Install a 3A fused jumper wire between the signal circuit terminal G and the ground circuit terminal C. Verify the scan tool hazard lamp switch parameter is Active.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.
- If all circuits test normal, test or replace the turn signal/multifunction switch