Circuit/System Testing
- Ignition OFF, disconnect the EOP switch.
- Ignition OFF, test for less than 1 ohm of resistance between the low reference circuit and ground.
- If greater than 1 ohm, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the PCM.
- Ignition ON, install a 3-amp fused jumper wire between the signal circuit and the low reference circuit. Verify the scan tool Engine Oil Pressure Switch parameter is Low.
- If not Low, test the signal circuit of the EOP switch for an open/high resistance. If the circuit tests normal replace the PCM.
- If all circuits test normal, test or replace the EOP switch.