DTC B2983 (5) (HVAC Control Unit)
DTC B2983 or DTC indicator 5 : A problem in the recirculation control motor circuit, linkage, door, or motor
| DTC Description | DTC |
|---|---|
| B2983 A problem in the recirculation control motor circuit, linkage, door, or motor |
DTCs (AC)
- Problem verification
-1. Clear the DTCs with the HDS.
-2. Turn the vehicle to the OFF (LOCK) mode, then the ON mode.
-3. Do the Self-Diagnostic Function with the HDS or the HVAC control unit .
-4. Check for DTCs.
DTC Description DTC B2983 A problem in the recirculation control motor circuit, linkage, door, or motor Is DTC B2983 or 5 indicated?
YES
Go to step 2.
NO
Intermittent failure. Check for loose wires or poor connections on the recirculation control motor circuit.
- Open wire check (M REC line)
-1. Turn the vehicle to the OFF (LOCK) mode.
-2. Disconnect the following connectors.
HVAC control unit connector A (32P) Recirculation control motor 7P connector -3. Check for continuity between test points 1 and 2.
Test condition Vehicle OFF (LOCK) mode HVAC control unit connector A (32P): disconnected Recirculation control motor 7P connector: disconnected Test point 1 HVAC control unit connector A (32P) No. 15 Test point 2 Recirculation control motor 7P connector (female terminals) No. 6: Is there continuity?
YES
The M REC wire is not open. Go to step 3.
NO
Repair an open in the wire between the HVAC control unit and the recirculation control motor.
- Open wire check (M FRS line)
-1. Check for continuity between test points 1 and 2.
Test condition Vehicle OFF (LOCK) mode HVAC control unit connector A (32P): disconnected Recirculation control motor 7P connector: disconnected Test point 1 HVAC control unit connector A (32P) No. 16 Test point 2 Recirculation control motor 7P connector (female terminals) No. 7: Is there continuity?
YES
The M FRS wire is not open. Go to step 4.
NO
Repair an open in the wire between the HVAC control unit and the recirculation control motor.
- Shorted wire check (M REC line)
-1. Check for continuity between test points 1 and 2.
Test condition Vehicle OFF (LOCK) mode HVAC control unit connector A (32P): disconnected Recirculation control motor 7P connector: disconnected Test point 1 HVAC control unit connector A (32P) No. 15 Test point 2 Body ground Is there continuity?
YES
Repair a short to body ground in the wire between the HVAC control unit and the recirculation control motor.
NO
The M REC wire is OK. Go to step 5.
- Shorted wire check (M FRS line)
-1. Check for continuity between test points 1 and 2.
Test condition Vehicle OFF (LOCK) mode HVAC control unit connector A (32P): disconnected Recirculation control motor 7P connector: disconnected Test point 1 HVAC control unit connector A (32P) No. 16 Test point 2 Body ground Is there continuity?
YES
Repair a short to body ground in the wire between the HVAC control unit and the recirculation control motor.
NO
The M FRS wire is OK. Go to step 6.
- Recirculation control motor check
-1. Test the recirculation control motor .
Is the recirculation control motor OK?
YES
Replace the HVAC control unit .
NO
Replace the recirculation control motor , or repair the recirculation control linkage or door.