LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2021 >> Pilot Special Edition, AWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System - DTC Diagnostics >> DTC Troubleshooting >> DTC B1232 (1)

DTC B1232 (1)

DTC B1232 or DTC indicator 1  : A Short in the Evaporator Temperature Sensor Circuit (Front)

DTC Description DTC
B1232 A short in the evaporator temperature sensor circuit (front)  

DTC (AC)

  1. Problem verification

    - 1. Clear the DTC with the HDS.

    - 2. Turn the vehicle to the OFF (LOCK) mode then the ON mode.

    - 3. Do the Self-Diagnostic Function with the HDS or the HVAC control unit.

    - 4. Check for DTCs.

    DTC Description DTC
    B1232 A short in the evaporator temperature sensor circuit (front)  

    Is DTC B1232 or 1 indicated?

    YES 

    Go to step 2.

    NO 

    Intermittent failure. Check for loose wires or poor connections on the front evaporator temperature sensor circuit.

  2. Shorted wire check (TEVA line)

    - 1. Turn the vehicle to the OFF (LOCK) mode.

    - 2. Disconnect the following connectors.

    HVAC control unit connector C (12P)
    Front evaporator temperature sensor 2P connector

    - 3. Check for continuity between test points 1 and 2.

    Test condition Vehicle OFF (LOCK) mode
    HVAC control unit connector C (12P): disconnected
    Front evaporator temperature sensor 2P connector: disconnected
    Test point 1 HVAC control unit connector C (12P) No. 11
    Test point 2 Body ground

    Is there continuity?

    YES 

    Repair a short to body ground in the wire between the HVAC control unit and the front evaporator temperature sensor.

    NO 

    The TEVA wire is not shorted. Go to step 3.

  3. Shorted wire check (TEVA line to SENSOR(COM) line)

    - 1. Disconnect the following connector.

    HVAC control unit connector A (32P)

    - 2. Check for continuity between test points 1 and 2.

    Test condition Vehicle OFF (LOCK) mode
    HVAC control unit connector A (32P): disconnected
    HVAC control unit connector C (12P): disconnected
    Front evaporator temperature sensor 2P connector: disconnected
    Test point 1 HVAC control unit connector A (32P) No. 18
    Test point 2 HVAC control unit connector C (12P) No. 11

    Is there continuity?

    YES 

    Repair a short in the wires between the HVAC control unit and the front evaporator temperature sensor.

    NO 

    The TEVA wire to SENSOR(COM) wire are OK. Go to step 4.

  4. Front evaporator temperature sensor check

    - 1. Test the front evaporator temperature sensor.

    Is the front evaporator temperature sensor OK?

    YES 

    Replace the HVAC control unit .

    NO 

    Replace the front evaporator temperature sensor - Refer to: Evaporator Temperature Sensor Removal, Installation, and Test, or Rear Evaporator Temperature Sensor Removal, Installation, and Test .