LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2021 >> HR-V EX-L, FWD >> Repair and Diagnosis >> Brakes >> Traction Control >> VSA System - DTC Diagnostics >> DTC Troubleshooting >> DTC 81-20

DTC 81-20

DTC 81-20  : Acceleration Sensor (Inside of Modulator-Control Unit) Internal Circuit Malfunction

NOTE: 

DTC Description DTC Freeze Frame
81-20 Acceleration Sensor (Inside of Modulator-Control Unit) Internal Circuit Malfunction    

DTCs (VSA)

  1. Problem verification

    -1. Park the vehicle on a flat and level surface.

    -2. Turn the vehicle to the ON mode.

    -3. Clear the DTC with the HDS.

    -4. Turn the vehicle to the OFF (LOCK) mode, then the ON mode.

    -5. Test-drive the vehicle at 6 mph (10 km/h) or more.

    NOTE:  Drive the vehicle on the road, not on a lift.

    -6. Check for DTCs with the HDS.

    DTC Description DTC Freeze Frame
    81-20 Acceleration Sensor (Inside of Modulator-Control Unit) Internal Circuit Malfunction    

    Is DTC 81-20 indicated?

    YES 

    The failure is duplicated. Go to step 2.

    NO 

    Intermittent failure, the system is OK at this time. Refer to intermittent failures troubleshooting .

  2. VSA modulator-control unit check (update)

    -1. Update the VSA modulator-control unit if it does not have the latest software .

    -2. Turn the vehicle to the OFF (LOCK) mode, then the ON mode.

    -3. Test-drive the vehicle at 6 mph (10 km/h) or more.

    NOTE:  Drive the vehicle on the road, not on a lift.

    -4. Check for DTCs with the HDS.

    DTC Description DTC Freeze Frame
         

    Is DTC 81-20 indicated?

    YES 

    Check for loose terminals in the VSA modulator-control unit 21P connector. If the VSA modulator-control unit was updated and the symptom/indication is still present, replace the VSA modulator-control unit .

    NO 

    Troubleshooting is complete. If any other DTCs are indicated, go to the indicated DTCs troubleshooting.