LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2021 >> Clarity Plug-In Hybrid >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Battery Management Systems >> Battery Management System - Diagnostics (P262B - U160D) & Advanced Diagnostics (P0480 - P0C90) (Plug In) >> DTC Troubleshooting >> DTC U0081 (131) (Battery Condition Monitor Module A)

DTC U0081 (131) (Battery Condition Monitor Module A)

DTC U0081  : EP-CAN 2 Malfunction (Battery Condition Monitor Module A Bus-Off)

NOTE: Before you troubleshoot, review the general troubleshooting information .
DTC Description Confirmed DTC Pending DTC Freeze Frame
U0081 EP-CAN 2 Malfunction (Battery Condition Monitor Module A Bus-Off)      

DTC (Electric Powertrain)

  1. Problem verification

    -1. Turn the vehicle to the ON mode.

    -2. Clear the DTC with the HDS.

    -3. Turn the vehicle to the OFF (LOCK) mode.

    -4. Turn the vehicle to the ON mode.

    -5. Check for Pending or Confirmed DTCs with the HDS.

    DTC Description Confirmed DTC Pending DTC Freeze Frame
    U0081 EP-CAN 2 Malfunction (Battery Condition Monitor Module A Bus-Off)      

    Is DTC U0081 indicated?

    YES 

    Go to step 2.

    NO 

    Intermittent failure, the system is OK at this time. Check for poor connections or loose terminals at battery condition monitor module A and battery condition monitor module B. If the freeze data/on-board snapshot of this DTC is recorded, try to reproduce the failure under the same conditions with the freeze data/on-board snapshot.

  2. Shorted wire check (EPP-CAN B_H line to EPP-CAN B_L line)

    -1. Turn the vehicle to the OFF (LOCK) mode.

    -2. Do the 12 volt battery terminal disconnection procedure .

    -3. Remove the service plug .

    -4. Remove the IPU .

    -5. Remove the IPU cover .

    -6. Disconnect the following connectors.

    Battery condition monitor module A connector G (24P)
    Battery condition monitor module B connector G (24P)

    -7. Check for continuity between test points 1 and 2.

    Test condition Vehicle OFF (LOCK) mode
      Battery condition monitor module A connector G (24P): disconnected
      Battery condition monitor module B connector G (24P): disconnected
    Test point 1 Battery condition monitor module A connector G (24P) No. 10
    Test point 2 Battery condition monitor module A connector G (24P) No. 22

    Is there continuity?

    YES 

    Repair a short in the EPP-CAN B_H to EPP-CAN B_L wires between battery condition monitor module A and battery condition monitor module B.

    NO 

    Go to step 3.

  3. Shorted wire check (EPP-CAN B_H line, EPP-CAN B_L line)

    -1. Check for continuity between test points 1 and 2.

    Test condition Vehicle OFF (LOCK) mode
      Battery condition monitor module A connector G (24P): disconnected
      Battery condition monitor module B connector G (24P): disconnected
    Test point 1 Battery condition monitor module A connector G (24P) No. 10
    Test point 2 Body ground
    Test point 1 Battery condition monitor module A connector G (24P) No. 22
    Test point 2 Body ground

    Is there continuity?

    YES 

    Repair a short in the EPP-CAN B_H wire and/or the EPP-CAN B_L wire between battery condition monitor module A and battery condition monitor module B.

    NO 

    Go to step 4.

  4. Battery condition monitor module B check

    -1. Reconnect battery condition monitor module A connector G (24P).

    NOTE: Do not connect battery condition monitor module B connector G (24P).

    -2. Install the IPU cover .

    -3. Install the IPU .

    -4. Install the service plug .

    -5. Do the 12 volt battery terminal reconnection procedure .

    -6. Turn the vehicle to the ON mode.

    -7. Clear the DTC with the HDS.

    -8. Turn the vehicle to the OFF (LOCK) mode.

    -9. Turn the vehicle to the ON mode.

    -10. Check for Pending or Confirmed DTCs with the HDS.

    DTC Description Confirmed DTC Pending DTC Freeze Frame
    U0081 EP-CAN 2 Malfunction (Battery Condition Monitor Module A Bus-Off)      

    Is DTC U0081 indicated?

    YES 

    Check for any authorized service information related to the DTC(s) or symptoms you are troubleshooting or substitute a known-good battery condition monitor module A .

    NO 

    Check for any authorized service information related to the DTC(s) or symptoms you are troubleshooting or substitute a known-good battery condition monitor module B .