LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2021 >> CR-V EX-L, AWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System - Testing & Troubleshooting (Except Hybrid) >> Symptom Troubleshooting >> Climate Control System Symptom Troubleshooting - The blower and the heater controls and the A/C system do not work (2017 2018 2019)

Climate Control System Symptom Troubleshooting - The blower and the heater controls and the A/C system do not work (2017 2018 2019)

The blower and the heater controls and the A/C system do not work 

NOTE:  Do this troubleshooting procedure only if sent here by symptom troubleshooting index .

  1. Fuse check

    -1. Check the following fuse.

    Fuse No. D9 (10 A)
    Location Under-dash fuse/relay box

    Is the fuse OK?

    YES 

    Go to step 2.

    NO 

    Replace the fuse, and recheck. If the fuse blows again, repair a short in the No. D9 (10 A) fuse circuit.

  2. Open wire check (IG2 A/C line)

    -1. Disconnect the following connector.

    Climate control unit connector A (32P)

    -2. Turn the vehicle to the ON mode.

    -3. Measure the voltage between test points 1 and 2.

    Test condition Vehicle ON mode
    Climate control unit connector A (32P): disconnected
    Test point 1 Climate control unit connector A (32P) No. 32 
    Test point 2 Body ground

    Is there battery voltage?

    YES 

    The IG2 A/C wire is OK. Go to step 3.

    NO 

    Repair an open in the IG2 A/C wire.

  3. Open wire check (GND line)

    -1. Turn the vehicle to the OFF (LOCK) mode.

    -2. Check for continuity between test points 1 and 2.

    Test condition Vehicle OFF (LOCK) mode
    Climate control unit connector A (32P): disconnected
    Test point 1 Climate control unit connector A (32P) No. 28 
    Test point 2 Body ground

    Is there continuity?

    YES 

    Replace the climate control unit .

    NO 

    Check for an open in the GND wire. If the wire is OK, check for poor ground at G402.