Vehicle does not recharge from motor regenerative system
WARNING: This page is about a different variant/trim than selected.
Probable cause(s)
- Traction motor defective: worn or damaged:
-
- Stator
- Rotor
- Position sensor
- Position sensor line
- Terminal plate
- Sensor harness
- 3-phase wires
- Traction motor defective; faulty installations:
-
- Stator
- Position sensor
- Terminals
- 3-phase wire terminals
- Foreign material in traction motor
- Foreign material in PCU 3-phase connectors
- Countershaft worn or damaged
- Motor shaft worn or damaged
- Final gears worn or damaged
- Thrust washer seized, worn, or damaged
- Input shaft bearing, countershaft bearing, generator shaft bearing, motor shaft bearing, or differential carrier bearing defective
NOTE:
- Check the motor position sensor harness for poor connections, loose terminals, wear, and damage.
- Inspect the countershaft for wear and damage.
- Inspect the motor shaft for wear and damage.
- Check the final gears for wear and damage.
- Check the thrust washers for seizure, wear and damage.
- Check the bearings for the input shaft, the countershaft, the generator shaft, the motor shaft, and the differential carrier.
- Replace the transmission (e-CVT) .