DTC P145F, P1461, P1462, P24C1 (1.5 L Engine)
DTC P145F : EVAP Leak Check Module Pressure Sensor Range/Performance Problem DTC P1461 : EVAP Leak Check Module Pressure Sensor Shifts DTC P1462 : EVAP Leak Check Module Pressure Decompression Defect DTC P24C1 : Canister Change Over Valve Stuck Close
NOTE: Before you troubleshoot, review the general troubleshooting information .
| DTC Description | Confirmed DTC | Pending DTC |
|---|---|---|
| P145F EVAP Leak Check Module Pressure Sensor Range/Performance Problem | ||
| P1461 EVAP Leak Check Module Pressure Sensor Shifts | ||
| P1462 EVAP Leak Check Module Pressure Decompression Defect | ||
| P24C1 Canister Change Over Valve Stuck Close |
DTC (PGM-FI)
- Problem verification
-1. Turn the vehicle to the ON mode.
-2. Clear the DTC with the HDS.
-3. Turn the vehicle to the OFF (LOCK) mode.
-4. Turn the vehicle to the ON mode.
-5. Select the EVAP TEST (ELCM) in the INSPECTION MENU, then select EVAP Leak Check Module Test with the HDS.
EVAP TEST (ELCM)
Is the result OK?
YES
If the test result is PASSED, intermittent failure, the system is OK at this time. Check for poor connections or loose terminals at the EVAP leak check module and the PCM. If the on-board snapshot of this DTC is recorded, try to reproduce the failure under the same conditions with the on-board snapshot .
NO
The failure is duplicated. Go to step 2.
- EVAP leak check module drain hose check
-1. Remove the EVAP leak check module and the EVAP canister filter , then check the blockage in the drain hoses and the EVAP canister filter.
Are the parts OK?
YES
Replace the EVAP leak check module .
NO
Remove the blockage from them, or replace the part (s) if needed.