DTC B2A60-98, P2583-98

DTC B2A60-98  : Multipurpose Camera Unit Temperature Too High

DTC P2583-98  : Millimeter Wave Radar Temperature Too High

NOTE: 

DTC Description DTC
B2A60-98 Multipurpose Camera Unit Temperature Too High  
P2583-98 Millimeter Wave Radar Temperature Too High  

DTC (IDAS)

  1. Inspecting the temperature in the control unit

    -1. Turn the vehicle to the ON mode.

    -2. Check the parameter(s) of the internal temperatures of the millimeter wave radar and the multipurpose camera unit with the HDS.

    Is the temperature 185 deg.F (85 deg.C) or less?

    YES 

    Go to step 2.

    NO 

    Cool the control unit until the internal temperature is 167 deg.F (75 deg.C) or less. Clear the DTC with the HDS.

  2. Problem verification:

    NOTE:  If the control unit has an internal temperature of 167 deg.F (75 deg.C) or more, cool the control unit until the internal temperature is 167 deg.F (75 deg.C) or less.

    -1. Clear the DTC with the HDS.

    -2. Turn the vehicle to the OFF (LOCK) mode.

    -3. Turn the vehicle to the ON mode, then wait for at least 6 seconds.

    -4. Check for DTCs with the HDS.

    DTC Description DTC
    B2A60-98 Multipurpose Camera Unit Temperature Too High  
    P2583-98 Millimeter Wave Radar Temperature Too High  

    Is DTC B2A60-98 or P2583-98 indicated?

    YES 

    The failure is duplicated. Faulty a control unit, replace the control unit related to the DTC.

    NO 

    Intermittent failure, the system is OK at this time. The control unit was temporarily in a high temperature state.