LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2018 >> Fit EX, Standard Trans >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Gauges - Testing & Troubleshooting >> How To Information >> Gauges Self-Diagnostic Function >> Entering the Self-Diagnostic Function (Manual Method)

Entering the Self-Diagnostic Function (Manual Method)

Before doing the self-diagnostic function, make sure the No. B29 (10 A) fuse in the under-hood fuse/relay box, and No. C34 (7.5 A) fuse in the under-dash fuse/relay box are OK.

1. Press and hold the SEL/RESET switch

2. Turn the combination light switch to the PARKING position (

GHH81944Courtesy of HONDA, U.S.A., INC.

)

3. Turn the vehicle to the ON mode

4. Within 5 sec., turn the combination light switch OFF, then to the PARKING position (

GHH81944Courtesy of HONDA, U.S.A., INC.

) and OFF again

5. Within 5 sec., release the SEL/RESET switch, and then repeatedly press and release the switch three times.

NOTE: 

GHH81945Courtesy of HONDA, U.S.A., INC.