Econ Switch: Test
- Driver's Dashboard Lower Cover - Remove
- ECON Switch - Test
1. Check for continuity between the terminals in each switch position according to the table. - Make sure the correct test lead (+ or -) is placed on the terminal.
- When checking for continuity across the diode, use the diode setting (
) on the digital volt/ohm meter to check the diode bias.
- Remember this important operating characteristic; diode bias causes a diode to fully conduct electricity in one direction (forward), while not at all in the opposite direction (reverse).
2. If the continuity is not as specified, replace the ECON Switch - Removal and Installation (A).
- All Removed Parts - Install