Front Air Mix Control Motor Test
Special Tools Required
Backprobe Set 07SAZ-001000A
NOTE:
Before testing, check for HVAC DTCs (see HOW TO CHECK FOR DTCS WITH THE HDS
).
- Disconnect the 7P connector from the front air mix control motor.NOTE: Incorrectly applying power and ground to the front air mix control motor will damage it. Follow the instructions carefully.
- Connect battery power to terminal No. 7 of the front air mix control motor, and ground terminal No. 6; the front air mix control motor should run, and stop at Max Cool. If it does not, reverse the connections; the front air mix control motor should run, and stop at Max Hot. When the front air mix control motor stops running, disconnect battery power immediately.
- If the front air mix control motor did not run in step 2, remove it, then check the front air mix control linkage and door for smooth movement.
- If the linkage and door move smoothly, replace the front air mix control motor (see FRONT AIR MIX CONTROL MOTOR REPLACEMENT ).
- If the linkage or door sticks or binds, repair them as needed.
- If the front air mix control motor runs smoothly, go to step 4.
- Measure the resistance between terminals No. 1 and No. 3. It should be between 4.2 to 7.8 kΩ.
- Reconnect the front air mix control motor 7P connector, then turn the ignition switch to ON (II).
- Using the backprobe set, measure the voltage between terminals No. 3 and No. 5.
Max Cool: about 1.0 V
Max Hot: about 4.0 V
- If either the resistance or voltage readings are not as specified, replace the front air mix control motor (see FRONT AIR MIX CONTROL MOTOR REPLACEMENT ).