With multi-information display
- Turn the ignition switch to ON (II).
- Push the INFO (↑/↓) button to select the "CUSTOMIZE SETTINGS", then push the SEL/RESET button.
- While in the customizing mode, select the "CHG SETTING", and enter the "METER SETUP". Then select the "ADJUST OUTSIDE TEMP. DISPLAY", and calibrate the value with the SEL/RESET switch and the INFO (↑/↓) switch.
- When the desired correction value appears on the display, release the button, and the recalibrated outside air temperature will be displayed.NOTE: The recalibration temperature is not the value the sensor sees. Therefore the temperature can only be adjusted ±5° from sensors.
Example:
Incorrect value = 68°F (20°C)
Desired correction value = +2°F(+1°C)
Correct value = 70°F (21°C)
Desired correction value = -2°F (-1°C)
Correct value = 66°F (19°C)
NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the true temperature. - The snowmark is displayed when the temperature is 38°F (4°C) or less the first time you turn the ignition switch to ON (II).
Without multi-information display
- Turn the ignition switch to ON (II).
- Select the odometer/trip A or odometer/trip B display.
- Select the outside air temperature display and press and hold the SEL/RESET switch for 10 seconds. While you continue to hold the button, the display scrolls through temperature settings from +5°F to -5°F (or +3°C to -3°C) as shown in illustration.
- When the desired correction value appears on the display, release the button, and the recalibrated outside air temperature is displayed.
Each time a desired correction value is entered, it replaces the previous value.
NOTE: The recalibration temperature is not the value the sensor sees. Therefore the temperature can only be adjusted ±5° from sensors.Example:
Incorrect value = 68°F (20°C)
Desired correction value = +2°F (+1°C)
Correct value = 70°F (21°C)
Desired correction value = -2°F (-1°C)
Correct value = 66°F (19°C)
NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the true temperature.