Front Air Mix Control Motor Test

Special Tools Required 

Backprobe Set 07SAZ-001000A (2)

NOTE: Before testing, check for HVAC DTCs (see HOW TO CHECK FOR DTCS WITH THE HDS  ).
  1. Disconnect the 7P connector from the front air mix control motor.
    NOTE: Incorrectly applying power and ground to the front air mix control motor will damage it. Follow the instructions carefully.
  2. Connect battery power to terminal No. 1 of the front air mix control motor, and ground terminal No. 2; the front air mix control motor should run, and stop at Max Cool. If it doesn't, reverse the connections; the front air mix control motor should run, and stop at Max Hot. When the front air mix control motor stops running, disconnect battery power immediately.
    Fig 1: Identifying Front Air Mix Control Motor Terminals
    G08090284Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. If the front air mix control motor did not run in step  2, remove it, then check the front air mix control linkage and door for smooth movement.
    • If the linkage and door move smoothly, replace the front air mix control motor (see FRONT AIR MIX CONTROL MOTOR REPLACEMENT  ).
    • If the linkage or door sticks or binds, repair them as needed.
    • If the front air mix control motor runs smoothly, go to step 4.
  4. Measure the resistance between terminals No. 5 and No. 7. It should be between 4.2 to 7.8 kΩ.
  5. Reconnect the front air mix control motor 7P connector, then turn the ignition switch to ON (II).
  6. Using the backprobe set, measure the voltage between terminals No. 3 and No. 5.

    Max Cool: about 0.5 V 

    Max Hot: about 4.5 V 

  7. If either the resistance or voltage readings are not as specified, replace the front air mix control motor (see FRONT AIR MIX CONTROL MOTOR REPLACEMENT  ).