Outside Air Temperature Indicator Calibration: Calibration
The outside air temperature indicator's displayed temperature can be recalibrated ±5°F (±3°C) to meet the customer's expectations.
- Turn the ignition switch to ON (II).
- Push and hold the INFORMATION (NEXT or PREVIOUS) button for at least 3 seconds to enter the customizing mode.
- While in the customizing mode, select the CHG SETTING, and enter the METER SETUP. Then select the ADJUST OUTSIDE TEMP. DISPLAY, and calibrate the value with the SEL/RESET button and the INFORMATION (NEXT or PREVIOUS) button.
- When the desired correction value appears on the display, release the button, and the recalibrated outside air temperature will be displayed.NOTE: The recalibration temperature is not the value the sensor sees.
Therefore the temperature can only be adjusted ±5 degrees from sensors.
Example:
Incorrect value = 68°F (20°C)
Desired correction value = +2°F (+1C°C)
Correct value = 70°F (21°C)
Desired correction value = -2°F (-1°C)
Correct value = 66°F (19°C)
NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the true temperature. - The snow mark is displayed when the temperature is 37°F (3°C) or less the first time you turn the ignition switch to ON (II).