LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2014 >> Pilot EX-L, FWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Gauges >> DTC Troubleshooting - Except USA model >> U1288: Gauge Control Module Lost Communication With PARKSR

U1288: Gauge Control Module Lost Communication With PARKSR

NOTE: If you are troubleshooting multiple DTCs, be sure to follow the instructions in B-CAN System Diagnosis Test Mode A (see TROUBLESHOOTING - B-CAN SYSTEM DIAGNOSIS TEST MODE A ).
  1. Clear the DTCs with the HDS.
  2. Turn the ignition switch to LOCK (0) and then back to ON (II).
  3. Wait for at least 6 seconds.
  4. Check for DTCs with the HDS.

    Is DTC U1288 indicated? 

    YES  -Go to step 5.

    NO  -Intermittent failure, the system is OK at this time. Check for loose or poor connections between the gauge control module and the parking and back-up sensor control unit.

  5. From the BODY ELECTRICAL SYSTEM SELECT menu, select B-CAN CONTROL UNITS INFORMATION, and then select CHECK CONNECTED CONTROL UNITS.

    Is the parking sensor module detected? 

    YES  -Go to step  9.

    NO  -Go to step 6.

  6. Measure the voltage between body ground and parking and back-up sensor control unit 24P connector terminal No. 13.
    Fig 1: Measuring Voltage Between Body Ground And Parking And Back-Up Sensor Control Unit 24P Connector Terminal No. 13
    G08089148Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there battery voltage? 

    YES  -Go to step  8.

    NO  -Go to step 7.

  7. Check the No. 8 (7.5 A) fuse in the under-dash fuse/relay box.

    Is the fuse OK? 

    YES  -Repair an open or high resistance in the No. 8 (7.5 A) fuse circuit.

    NO  -Replace the fuse. If the fuse blows again, repair a short to ground in the No. 8 (7.5 A) fuse circuit.

  8. Measure the voltage between body ground and parking and back-up sensor control unit 24P connector terminal No. 6 and No. 24 individually.
    Fig 2: Measuring Voltage Between Body Ground And Parking And Back-Up Sensor Control Unit 24P Connector Terminal No. 6 And 24
    G08089149Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there less than 0.2 V? 

    YES  -Go to step 9.

    NO  -Repair an open or high resistance in the ground wire or poor ground (G403).

  9. Turn the ignition switch to LOCK (0).
  10. Disconnect the parking and back-up sensor control unit 24P connector.
  11. Disconnect the gauge control module 32P connector.
  12. Check for continuity between parking and back-up sensor control unit 24P connector terminals No. 7 and No. 8 and gauge control module 32P connector terminals No. 19 and No. 20 respectively.
    Fig 3: Checking Continuity Between Parking And Back-Up Sensor Control Unit 24P Connector Terminals And Gauge Control Module 32P Connector Terminals
    G08089150Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there continuity? 

    YES  -Replace the parking and back-up sensor control unit (see PARKING AND BACK-UP SENSOR CONTROL UNIT INPUT TEST/REPLACEMENT ).

    NO  -An open or poor connection in the B-CAN wire between the gauge control module and the parking and back-up sensor control unit.