Radiator and A/C Condenser Fan Low Speed Circuit Troubleshooting
- Do not use this troubleshooting procedure if the A/C compressor is inoperative. Refer to the Symptom Troubleshooting Index .
- Before doing symptom troubleshooting, check for powertrain DTCs (see GENERAL TROUBLESHOOTING INFORMATION ).
- Check the No. 30 (30 A) and the No. 10 (7.5 A) fuses in the under-dash fuse/relay box.
Are the fuses OK?
YES -Go to step 2.
NO -Replace the fuse(s), and recheck. If the fuse(s) blow again, check for a short in the No. 30 (30 A) and No. 10 (7.5 A) fuses circuit.
- Remove the radiator fan relay from the auxiliary under-hood relay box, and test it (see
POWER RELAY TEST
).
Is the relay OK?
YES -Go to step 3.
NO -Replace the radiator fan relay.
- Connect the HDS to the DLC.
- Turn the ignition switch to ON (II).
- Turn the A/C and FAN to ON on the climate control unit.
- Check the FAN LOW CTRL in the PGM-FI Data List with the HDS.
Is the FAN LOW CTRL on?
YES -Go to step 7.
NO -Substitute a known-good PCM (see SUBSTITUTING THE PCM ), and retest. If the symptom/indication goes away with a known-good PCM, replace the original PCM (see PCM REPLACEMENT ).
- Turn the A/C switch and the fan control switch OFF, then turn the ignition switch to LOCK (0).
- Measure the voltage between radiator fan relay 4P socket terminal No. 1 and body ground.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there battery voltage?
YES -Go to step 9.
NO -Repair an open in the wire between the No. 30 (30 A) fuse in the under-dash fuse/relay box and the radiator fan relay.
- Connect radiator fan relay 4P socket terminals No. 1 and No. 2 with a jumper wire.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Do the radiator and A/C condenser fans run?
YES -Go to step 10.
NO -Go to step 19.
- Disconnect the jumper wire.
- Turn the ignition switch to ON (II).
- Measure the voltage between radiator fan relay 4P socket terminal No. 4 and body ground.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there battery voltage?
YES -Go to step 13.
NO -Repair an open in the wire between the No. 10 (7.5 A) fuse in the under-dash fuse/relay box, A/C diode A and the radiator fan relay.
- Turn the ignition switch to LOCK (0).
- Reinstall the radiator fan relay.
- Jump the SCS line with the HDS.NOTE: This step must be done to protect the powertrain control module (PCM) from damage.
- Disconnect PCM connector A (49P).
- Connect PCM connector A (49P) terminal No. 44 to body ground with a jumper wire.
- Turn the ignition switch to ON (II).
Do the radiator and A/C condenser fans run on low?
YES -Check for loose wires or poor connections at PCM connector A (49P). If the connections are good, substitute a known-good PCM (see SUBSTITUTING THE PCM ), and recheck. If the symptom/indication goes away, replace the original PCM (see PCM REPLACEMENT ), then do the PCM idle learn procedure (see PCM IDLE LEARN PROCEDURE ).
NO -Repair an open in the wire between the radiator fan relay and the PCM.
- Disconnect the jumper wire.
- Reinstall the radiator fan relay.
- Disconnect the radiator fan motor 2P connector.
- Turn the ignition switch to ON (II), then turn the A/C switch and fan control switch ON.
- Measure the voltage between radiator fan motor 2P connector terminal No. 2 and body ground.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there battery voltage?
YES -Go to step 24.
NO -Repair an open in the wire between the radiator fan relay and the radiator fan motor.
- Turn the A/C switch and fan control switch OFF, then turn the ignition switch to LOCK (0).
- Test the radiator fan motor (see
FAN MOTOR TEST
).
Is the motor OK?
YES -Go to step 26.
NO -Replace the radiator fan motor (see FAN, FAN MOTOR, AND SHROUD REMOVAL AND INSTALLATION ).
- Remove the fan control relay from the auxiliary under-hood fuse/relay box, and test it (see
POWER RELAY TEST
).
Is the relay OK?
YES -Go to step 27.
NO -Replace the fan control relay.
- Turn the ignition switch ON (II), then turn the A/C switch and fan control switch ON.
- Measure the voltage between fan control relay 5P socket terminal No. 1 and body ground.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there battery voltage?
YES -Go to step 29.
NO -Repair an open in the wire between the radiator fan motor and the fan control relay.
- Turn the A/C switch and fan control switch OFF, then turn the ignition switch to LOCK (0).
- Disconnect the A/C condenser fan motor 2P connector.
- Check for continuity between fan control relay 5P socket terminal No. 4 and A/C condenser fan motor 2P connector terminal No. 2.Fig 7: Checking Continuity Between Fan Control Relay 5P Socket Terminal No. 4 And A/C Condenser Fan Motor 2P Connector Terminal No. 2
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Go to step 32.
NO -Repair an open in the wire between the fan control relay and the A/C condenser motor fan.
- Check for continuity between A/C condenser fan motor 2P connector terminal No. 1 and body ground.Fig 8: Checking Continuity Between A/C Condenser Fan Motor 2P Connector Terminal No. 1 And Body Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Replace the A/C condenser fan motor (see FAN, FAN MOTOR, AND SHROUD REMOVAL AND INSTALLATION ).
NO -Check for an open in the wire between the A/C condenser fan and body ground. If the wire is OK, check for poor ground at G401 (see CONNECTOR TO FUSE/RELAY BOX INDEX ).