LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2013 >> CR-Z Base, Automatic CVT Trans >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> IMA System >> System Description >> MCM Inputs and Outputs at Connector E (31P)

MCM Inputs and Outputs at Connector E (31P)

Fig 1: Identifying MCM Connector E (31P) Terminals Layout
G06950234Courtesy of AMERICAN HONDA MOTOR CO., INC.
TERMINALS DESCRIPTION CHART

Terminal number Wire color Terminal name Description Signal
1 WHT VHB8 (HIGH VOLTAGE BATTERY 8 VOLTAGE) Battery module No. 8 terminal voltage input With battery module switch ON: about 16.5 V (between VHB7 and VHB8)
2 BLU VHB7 (HIGH VOLTAGE BATTERY 7 VOLTAGE) Battery module No. 7 terminal voltage input With battery module switch ON: about 16.5 V (between VHB7 and VHB8)
3 Not used Not used    
4 Not used Not used    
5 Not used Not used    
6 Not used Not used    
7 Not used Not used    
8 GRN/RED VHB4 (HIGH VOLTAGE BATTERY 4 VOLTAGE) Battery module No. 4 terminal voltage input With battery module switch ON: about 16.5 V (between VHB3 and VHB4)
9 GRN VHB3(HIGH VOLTAGE BATTERY 3 VOLTAGE) Battery module No. 3 terminal voltage input With battery module switch ON: about 16.5 V (between VHB2 and VHB3)
10 Not used Not used    
11 Not used Not used    
12 YEL VHB6 (HIGH VOLTAGE BATTERY 6 VOLTAGE) Battery module No. 6 terminal voltage input With battery module switch ON: about 16.5 V (between VHB6 and VHB7)
13 GRN/BLK VHB5 (HIGH VOLTAGE BATTERY 5 VOLTAGE) Battery module No. 5 terminal voltage input With battery module switch ON: about 16.5 V (between VHB5 and VHB6)
14 Not used Not used    
15 Not used Not used    
16 Not used Not used    
17 Not used Not used    
18 Not used Not used    
19 Not used Not used    
20 BLK VHB2 (HIGH VOLTAGE BATTERY 2 VOLTAGE) Battery module No. 2 terminal voltage input With battery module switch ON: about 16.5 V (between VHB1 and VHB2)
21 GRN/YEL VHB1 (HIGH VOLTAGE BATTERY 1 VOLTAGE) Battery module No. 1 terminal voltage input With battery module switch ON: about 16.5 V (between VHB0 and VHB1)
22 Not used Not used    
23 Not used Not used    
24 Not used Not used    
25 Not used Not used    
26 Not used Not used    
27 Not used Not used    
28 Not used Not used    
29 Not used Not used    
30 Not used Not used    
31 RED VHB0 (HIGH VOLTAGE BATTERY 0 VOLTAGE) Battery module No. 0 terminal voltage input With battery module switch ON: about 16.5 V (between VHB0 and VHB1)