Engine Restart Conditions After Auto Idle Stop (CVT model)

When any of the following conditions are met, the engine restarts after idle stop.

ENGINE RESTART CONDITIONS

Engine Restart Conditions Parameter (HDS)
Engine Start Switch
Shift position is in N, and ignition switch is turned to START (III).
STARTER SWITCH
Vehicle Speed
  • Acceleration exceeds 12 mph (20 km/h).
  • Vehicle speed pulse generated during idle stop.
VEHICLE SPEED
Transmission
Shift position is P or R.
  • A/T P SWITCH
  • A/T R SWITCH
Brake System
Pedal is released.
BRAKE SWITCH
Accelerator Pedal
Accelerator pedal is pressed (APP sensor is 0.2%).
APP SENSOR
IMA System
SOC is 37% or less, (battery module SOC indicator shows three segments or less.)
SOC
Brake Booster Pressure
Brake booster pressure is not within 310-350 mmHg at 0 mph (0 km/h). (Threshold depends on vehicle speed and atmospheric pressure.)
BRAKE BOOSTER PRESSURE SENSOR (S) A+B
Climate Control System
  • Defogger switch is ON.
  • Idle stop cancellation counter reaches zero.
  • IDLE STOP PERMIT TIME (A/C)
  • IDLE STOP RELEASE COUNTER