Troubleshooting Circuits at the MCM Connectors
Special Tools Required
- Digital Multimeter KS-AHM-32-003*
- Backprobe Set 07SAZ-001000A (2)
* Available through the Honda Tool and Equipment Program 888-424-6857
- Remove the IPU cover (see IPU COVER REMOVAL/INSTALLATION ).
- Remove the PCU lid, the PCU busplate, and the PCU cover (see IPU CASE REMOVAL/INSTALLATION ).
- Connect the backprope adapters (A) to the stacking patch cords (B), and connect the cords to a digital multimeter.