Radiator and A/C Condenser Fan Low Speed Circuit Troubleshooting

NOTE:
  1. Check the No. B10 (7.5 A) and the No. B30 (30 A) fuse in the under-dash fuse/relay box.

    Are the fuses OK? 

    YES  -Go to step  2.

    NO  -Replace the fuse, and recheck. If the fuse blow again, check for a short in the No.B10 (7.5 A) fuse and the No. B30 (30 A) fuse circuits.

  2. Remove the radiator fan relay from auxiliary under-hood relay box B, and test it (see POWER RELAY TEST ).

    Is the relay OK? 

    YES  -Go to step  3.

    NO  -Replace the radiator fan relay.

  3. Connect the HDS to the DLC.
  4. Turn the ignition switch to ON (II).
  5. Turn on the A/C.
  6. Check the FAN LOW CTRL in the PGM-FI Data List with the HDS.

    Is the FAN LOW CTRL on? 

    YES  -Go to step  8.

    NO  -Substitute a known-good ECM/PCM (see SUBSTITUTING THE ECM/PCM ), and recheck. If the symptom/indication goes away with a known-good ECM/PCM, replace the original ECM/PCM (see ECM/PCM REPLACEMENT ).

  7. Turn the A/C switch and the fan control switch OFF, then turn the ignition switch to LOCK (0).
  8. Measure the voltage between radiator fan relay 4P socket terminal No. 1 and body ground.
    Fig 1: Measuring Voltage Between Radiator Fan Relay 4P Socket Terminal No. 1 And Body Ground
    G06953666Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there battery voltage? 

    YES  -Go to step  9.

    NO  -Replace the under-dash fuse/relay box.

  9. Connect radiator fan relay 4P socket terminals No. 1 and No. 2 with a jumper wire.
    Fig 2: Connecting Radiator Fan Relay 4P Socket Terminals No. 1 And No. 2 With Jumper Wire
    G06953667Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Do the radiator and A/C condenser fans run? 

    YES  -Go to step  10.

    NO  -Go to step  19.

  10. Disconnect the jumper wire.
  11. Turn the ignition switch to ON (II).
  12. Measure the voltage between radiator fan relay 4P socket terminal No. 7 and body ground.
    Fig 3: Measuring Voltage Between Radiator Fan Relay 4P Socket Terminal No. 7 And Body Ground
    G06953668Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there battery voltage? 

    YES  -Go to step  13.

    NO  -Repair an open in the wire between the No. B10 (7.5 A) fuse in the under-dash fuse/relay box, A/C diode B and the radiator fan relay.

  13. Turn the ignition switch to LOCK (0).
  14. Reinstall the radiator fan relay.
  15. Jump the SCS line with the HDS.
    NOTE: This step must be done to protect the ECM/PCM from damage.
  16. Disconnect ECM/PCM connector A (44P).
  17. Connect ECM/PCM connector A (44P) terminal No. 4 to body ground with a jumper wire.
    Fig 4: Connecting ECM/PCM Connector A (44P) Terminal No. 4 To Body Ground With Jumper Wire
    G06953669Courtesy of AMERICAN HONDA MOTOR CO., INC.
  18. Turn the ignition switch to ON (II).

    Do the radiator and A/C condenser fans run on LO? 

    YES  -Check for loose wires or poor connection at ECM/PCM connector A (44P). If the connection is good, substitute a known-good ECM/PCM (see SUBSTITUTING THE ECM/PCM ), and recheck. If the symptom/indication goes away, replace the original ECM/PCM (see ECM/PCM REPLACEMENT ), then do the ECM/PCM idle learn procedure (see ECM/PCM IDLE LEARN PROCEDURE ).

    NO  -Repair an open in the wire between the radiator fan relay and the ECM/PCM.

  19. Disconnect the jumper wire.
  20. Reinstall the radiator fan relay.
  21. Disconnect the radiator fan 2P connector.
  22. Turn the ignition switch to ON (II), then turn the A/C switch and the fan control switch ON.
  23. Measure the voltage between radiator fan 2P connector terminal No. 1 and body ground.
    Fig 5: Measuring Voltage Between Radiator Fan 2P Connector Terminal No. 1 And Body Ground
    G06953670Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there battery voltage? 

    YES  -Go to step  24.

    NO  -Repair an open in the wire between the radiator fan relay and the radiator fan.

  24. Turn the A/C switch and the fan control switch OFF, then turn the ignition switch to LOCK (0).
  25. Remove the fan control relay from auxiliary under-hood relay box A, and test it (see POWER RELAY TEST ).

    Is the relay OK? 

    YES  -Go to step  26.

    NO  -Replace the fan control relay.

  26. Check for continuity between radiator fan 2P connector terminal No. 2 and fan control relay 5P socket terminal No. 6.
    Fig 6: Checking Continuity Between Radiator Fan 2P Connector Terminal No. 2 And Fan Control Relay 5P Socket Terminal No. 6
    G06953671Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there continuity? 

    YES  -Go to step  27.

    NO  -Repair an open in the wire between the radiator fan and the fan control relay.

  27. Remove the radiator fan relay.
  28. Connect radiator fan relay 4P socket terminal No. 1 and No. 2 with a jumper wire.
    Fig 7: Connecting Radiator Fan Relay 4P Socket Terminal No. 1 And No. 2 With Jumper Wire
    G06953672Courtesy of AMERICAN HONDA MOTOR CO., INC.
  29. Connect fan control relay 5P socket terminal No. 6 to body ground with a jumper wire.
    Fig 8: Connecting Fan Control Relay 5P Socket Terminal No. 6 To Body Ground With Jumper Wire
    G06953673Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Does the radiator fan run on high? 

    YES  -Go to step  30.

    NO  -Replace the radiator fan motor (see FAN, FAN MOTOR, AND SHROUD REMOVAL AND INSTALLATION ).

  30. Disconnect the jumper wires.
  31. Disconnect the A/C condenser fan 2P connector.
  32. Check for continuity between fan control relay 5P socket terminal No. 14 and A/C condenser fan 2P connector terminal No. 1.
    Fig 9: Checking Continuity Between Fan Control Relay 5P Socket Terminal No. 14 And A/C Condenser Fan 2P Connector Terminal No. 1
    G06953674Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there continuity? 

    YES  -Go to step  33.

    NO  -Repair an open in the wire between the fan control relay and the A/C condenser fan.

  33. Check for continuity between A/C condenser fan 2P connector terminal No. 2 and body ground.
    Fig 10: Checking Continuity Between A/C Condenser Fan 2P Connector Terminal No. 2 And Body Ground
    G06953675Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there continuity? 

    YES  -Replace the A/C condenser fan motor (see FAN, FAN MOTOR, AND SHROUD REMOVAL AND INSTALLATION ).

    NO  -Check for an open in the wire between the A/C condenser fan and body ground. If the wire is OK, check for poor ground at G401 (see LEFT ENGINE COMPARTMENT WIRE HARNESS (BF) ).