DTC B1231 or DTC indicator G and AUTO: An Open in the Evaporator Temperature Sensor Circuit

  1. Clear the DTC with the HDS.
  2. Turn the ignition switch to LOCK (0), and then to ON (II).
  3. Do the Self-Diagnostic Function with the HDS (see HOW TO USE THE SELF-DIAGNOSTIC FUNCTION WITH THE HDS  ) or the climate control unit (see HOW TO USE THE SELF-DIAGNOSTIC FUNCTION WITHOUT THE HDS  ).
  4. Check for DTCs.

    Is DTC B1231 or G and AUTO indicated? 

    YES  -Go to step  5.

    NO  -Intermittent failure. Check for loose wires or poor connections on the evaporator temperature sensor circuit.

  5. Turn the ignition switch to LOCK (0).
  6. Remove the evaporator temperature sensor (see EVAPORATOR CORE REPLACEMENT  ), and test it (see EVAPORATOR TEMPERATURE SENSOR TEST  ).

    Is the evaporator temperature sensor OK? 

    YES  -With the evaporator temperature sensor disconnected, go to step  7.

    NO  -Replace the evaporator temperature sensor (see EVAPORATOR CORE REPLACEMENT  ).

  7. Disconnect the climate control unit 36P connector.
  8. Check for continuity between climate control unit 36P connector terminal No. 16 and evaporator temperature sensor 2P connector terminal No. 2.
    Fig 1: Checking Continuity Between Climate Control Unit 36P Connector Terminal No. 16 And Evaporator Temperature Sensor 2P Connector Terminal No. 2
    G06953631Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there continuity? 

    YES  -Go to step  9.

    NO  -Repair an open in the wire between the climate control unit and the evaporator temperature sensor.

  9. Check for continuity between climate control unit 36P connector terminal No. 12 and evaporator temperature sensor 2P connector terminal No. 1.
    Fig 2: Checking Continuity Between Climate Control Unit 36P Connector Terminal No. 12 And Evaporator Temperature Sensor 2P Connector Terminal No. 1
    G06953632Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there continuity? 

    YES  -Check for loose wires or poor connections at the climate control unit 36P connector and at the evaporator temperature sensor 2P connector, if the connections are good, substitute a known-good climate control unit, and recheck. If the symptom/indication goes away, replace the original climate control unit (see CLIMATE CONTROL UNIT REMOVAL/INSTALLATION  ).

    NO  -Repair an open in the wire between the climate control unit and the evaporator temperature sensor.