Select Arm Clearance Inspection
WARNING: This page is about a different variant/trim than selected.
- Measure the clearance between the select arm (A) and the Interlock (B) with a feeler gauge (C). If the clearance exceeds the service limit, go to step 2.
Standard: 0.01-0.21 mm (0.0004-0.0083 in)
Service Limit: 0.3 mm (0.012 in)
- Measure the width of the select arm.
- If the width is not within the standard, replace the select arm.
- If the width is within the standard, replace the interlock.
Standard: 12.9-13.0 mm (0.508-0.512 in)