Reverse Shift Fork Clearance Inspection
WARNING: This page is about a different variant/trim than selected.
- Measure the clearance between the reverse idler gear (A) and the reverse shift fork (B) with a feeler gauge (C). If the clearance exceeds the service limit, go to step 2.
Standard: 0.2-0.6 mm (0.008-0.024 in)
Service Limit: 1.2 mm (0.047 in)
- Measure the width of the reverse shift fork.
- If the width is not within the standard, replace the reverse shift fork.
- If the width is within the standard, replace the reverse idle gear.
Standard: 14.7-14.9 mm (0.579-0.587 in)