LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2013 >> CR-Z Base, Automatic CVT Trans >> Repair and Diagnosis >> Engine Mechanical >> Mechanical >> Engine Block >> Connecting Rod Bearing Replacement >> Connecting Rod Bearing Clearance Inspection

Connecting Rod Bearing Clearance Inspection

  1. Remove the bearing cap bridge (see CRANKSHAFT AND PISTON REMOVAL  ).
  2. Remove the connecting rod cap and the bearing half.
  3. Clean the connecting rod journal and the bearing half with a clean shop towel.
  4. Place one strip of plastigage across the rod journal.
  5. Reinstall the bearing half and connecting rod cap, and torque the bolts to 10 N.m (1.0 kgf.m, 7 lbf.ft) +90°.
    NOTE:
    • Apply new engine oil to the bolt threads and flanges.
    • Do not rotate the crankshaft during inspection.
  6. Remove the connecting rod cap and bearing half, and measure the widest part of the plastigage.

    Connecting Rod Bearing-to-Journal Oil Clearance 

    Standard (New): 0.020-0.038 mm (0.00079-0.00150 in) 

    Service Limit: 0.050 mm (0.00197 in) 

    Fig 1: Measuring Connecting Rod Bearing To Journal Oil Clearance
    G06949502Courtesy of AMERICAN HONDA MOTOR CO., INC.
  7. If the plastigage measures too wide or too narrow, remove the upper half of the bearing, install a new, complete bearing with the same color code, and recheck the clearance. Do not file, shim, or scrape the bearings or the caps to adjust clearance.
  8. If the plastigage shows the clearance is still incorrect, try the next larger or smaller bearing (the color listed above or below that one), and check clearance again. If the proper clearance cannot be obtained by using the appropriate larger or smaller bearing, replace the crankshaft (see CRANKSHAFT AND PISTON REMOVAL  ) and start over.