Immobilizer indicator does not go off
- Turn the ignition switch to LOCK (0).
- Connect the HDS to the data link connector (DLC).
- Turn the ignition switch to ON (II).
- From the SYSTEM SELECTION MENU, enter IMMOBI, select IMMOBILIZER SET UP, then select System Check, Number of Keys, and Status Log.
- Do the SYSTEM CHECK with the HDS.
Is N-1 indicated?
YES -Replace the gauge control module (see GAUGE CONTROL MODULE REPLACEMENT ).
NO -Substitute a known-good immobilizer-keyless control unit, then register it and recheck. If the symptom goes away, replace the original immobilizer-keyless control unit (see PROGRAMMING IMMOBILIZER-KEYLESS CONTROL UNIT ).