VSA activation indicator does not go off, and no DTCs are stored
- Turn the ignition switch to ON (II), and watch the VSA activation indicator.
Does VSA activation indicator go off within 2 seconds?
YES -Intermittent failure, the system is OK at this time. Refer to intermittent failures troubleshooting (see INTERMITTENT FAILURES ).
NO -Go to step 2.
- Turn the ignition switch to LOCK (0).
- Disconnect the VSA OFF switch 10P connector (see VSA OFF SWITCH TEST/REPLACEMENT ).
- Check the VSA OFF switch (see VSA OFF SWITCH TEST ).
Is the VSA OFF switch OK?
YES -Go to step 5.
NO -Replace the VSA OFF switch (see VSA OFF SWITCH TEST ). ■
- Disconnect gauge control module connector B (14P) (see GAUGE CONTROL MODULE REPLACEMENT ).
- Check for continuity between VSA OFF switch 10P connector terminal No. 2 and body ground.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Repair short to body ground between the gauge control module and the VSA OFF switch. ■
NO -Substitute a known-good gauge control module (see GAUGE CONTROL MODULE REPLACEMENT ), then go to step 1 and recheck. If it is OK, replace the original gauge control module (see GAUGE CONTROL MODULE REPLACEMENT ). ■