LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2012 >> Ridgeline RTL >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Gauges & Instrument Panels >> Gauges >> Self-diagnostic Function >> Entering the Self-Diagnostic Function

Entering the Self-Diagnostic Function

Before doing the self-diagnostic function, make sure the No. 7 (7.5 A) fuse, the No. 21 (7.5 A) fuse and the No. 32 (7.5 A) in the under-dash fuse/relay box.

  1. Push and hold the RESET switch button.
  2. Turn the lighting switch ON.
  3. Turn the ignition switch to ON (II).
  4. Within 5 sec, turn the lighting switch OFF, then ON and OFF again.
  5. Within 5 sec, release the RESET switch button, and then push and release the button three times repeatedly.
NOTE:
  • While in the self-diagnostic mode, the dash lights brightness controller operates normally.
  • While in the self-diagnostic mode, the RESET button is used to start the Beeper Drive Circuit Test and the Gauge Drive Circuit Check.
  • If the vehicle speed exceeds 1.2 mph (2 km/h) or the ignition switch is turned to LOCK (0), the self-diagnostic mode ends.
Fig 1: Identifying Blinking Pattern
G05968824Courtesy of AMERICAN HONDA MOTOR CO., INC.