ENABLE CONDITIONS

Condition Minimum Maximum
Elapsed time after engine start** 10 seconds -
Engine coolant temperature(1) 140°F (60°C) -
Battery voltage 10.5 V -
Fuel feedback Closed loop
No active DTCs P0101, P0102, P0103, P0107, P0108, P0117, P0118, P0134, P0135, P0154, P0155, P0300, P0301, P0302, P0303, P0304, P0305, P0306, P0335, P0339, P0351, P0352, P0353, P0354, P0355, P0356, P0443, P0451, P0452, P0453, P0496, P0497, P0498, P0499, P1109, P1128, P1129, P1172, P1174, P145C, P2195, P2197, P2227, P2228, P2229, P2237, P2238, P2240, P2241, P2243, P2245, P2247, P2249, P2251, P2252, P2254, P2255, P2279
Others The EVAP canister vent shut valve is open
The EVAP canister purge valve is closed (the system is not purging)
(1) Condition to start the purge control.